Max Output Power (kW)
Max Output DC Range (Volts)
Max Output DC Current (Amps)
Minimum Output Wire Size (DC BUS +, AWG)
Minimum Output Wire Size (DC BUS -, AWG)
Installation
1. Remove the screws and open the front door of the GSE SVS-100.
2. Locate the AC Input Terminal Block and the Chassis Grounding Connector.
Refer to Figure 4- 6 and Figure 4- 7.
3. Bring utility wires from the Utility Distribution Panel through conduit, and route them to the AC
Input Terminal Block and the Chassis Grounding Connector.
NOTE: The grounding wire should have insulation that is green or green with yellow stripe.
4. Ensure good electrical connection by tightening the all the screws properly.
5. Close the front door prior to switching on the utility power.
23435-W-03-01
SVS100 Installation, Operation and Maintenance Manual
Table 4-2 Output Characteristics for GSE SV100
Configuration
18
10
16-120
250
2/0
2/0
Webasto Charging Systems, Inc.