Measuring Line-To-Line Voltage; Table 4. Power Supply Cabinet Field Replaceable Parts - Webasto PosiCharge DVS Field Service Manual

Gse
Table of Contents

Advertisement

DVS/GSE

Table 4. Power Supply Cabinet Field Replaceable Parts

Part Name
Capacitor C1
Capacitor C2
Capacitor C3
Contactor K1
Fan, FAN2
Fan, FAN3
Fuse F1
Fuse F2
Fuse F3
Indicator Light, Green, DS1
Indicator Light, Yellow,
DS2
Indicator Light, Red, DS3
MOV 1
MOV 2
MOV 3
Rectifier D1
3.4.3
Measuring Line -to-Line Voltage
USE EXTREME CAUTION WHEN TROUBLESHOOTING DVS WITH
ANY PANEL REMOVED. ELECTRIC SHOCK CAN KILL: Touching live
electrical parts can cause fatal shocks or severe burns. The input power circuitry
and internal circuits are live whenever input power is on.
DANGER
Using extreme caution, measure voltages across K1.1/K1.2, K1.2/K1.3 and K1.1/K1.3 per
Figure 5. Confirm that all measurements conform to specifications in WCSI Doc. #08750-10.
If voltages are out of range, turn off power at utility power disconnect box, lock/tag utility
disconnect, and measure voltage between phases. If utility voltages do not conform to
specifications in WCSI Doc. #08750-10, contact facility electrician.
09030-78B
Part #
Part Name
07181
Rectifier D2
07181
Rectifier D3
07383
Relay K2
08477
Relay K3
06903
Terminal Block TB1
06903
Terminal Block TB2
06790
Terminal Block TB3
06790
Thermal Switch S1
06790
Thermal Switch S2
08443
Thermal Switch S3
08442
Thermal Switch S4
08441
Thermal Switch S5
08276
Thermal Switch S6
08276
Transformer T2
08276
Transformer T3
08159
Transformer, Main, T1
36
49
of
DVS
GSE
Field Service Manual
Part #
01165
01165
08157
08157
08167(6)/
08168(1)
08448
08167(6)/
08168(1)
08296
08296
05162
05162
05162
06971
08475
08476
08459
Webasto Charging Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading