4.9

Checklist

GSE SVS100 - INSTALLATION AND OPERATIONAL CHECKOUT
GSE
GSE
GSE
SVS100
SVS100
SVS100
Serial #
Serial #
Serial #
_ _ _ _ _
_ _ _ _
_ _ _ _
_
































SYSTEM CHECKED
BY – NAME /
SIGNATURE
CUSTOMER /
LOCATION
23435-W-03-01
SVS100 Installation, Operation and Maintenance Manual
GSE
SVS100
Serial #
_ _ _ _
_
_


CHECK UNIT IS SECURELY MOUNTED
CHECK AC CIRCUIT BREAKER RATING IS 20AAC @ 480VAC


600VAC
UTILITY CONNECTIONS PROPERLY INSTALLED WITH ALL
FASTENERS TIGHTENED:


ALL DC BUS CONNECTIONS PROPERLY INSTALLED WITH ALL
FASTENERS TIGHTENED:




CHECK OUTPUT CABLE STRAIN RELIEFS ARE SECURED.
BMID COMMUNICATION WIRING IS SECURE AND PROPERLY


CONNECTED


CHECK DC POWER SUPPLY CONNECTION
CHECK CONTROLLER BOARD CONNECTORS ARE SECURELY


AND PROPERLY INSTALLED.
CHECK BASSI CONTROLLER BOARD CONNECTORS ARE


SECURELY AND PROPERLY INSTALLED.


FRONT PANEL LED's WORK PROPERLY


DISPLAY IS FULLY OPERATIONAL


ALL FRONT PANEL CONTROL BUTTONS ARE FUNCTIONAL


LATEST APPLICATION CODE HAS BEEN LOADED
ALL SCREWS AND WASHERS PROPERLY INSTALLED ON


DOOR AND BACK PANEL
VERIFY GSE SVS100 CHARGES PROPERLY WHEN


CONNECTED TO VEHICLE
ALL HIGH CURRENT CABLES IN CHARGING PATH ARE


SECURELY FASTENED
21
CHECK AC TERMINAL BLOCK
CHECK CHASSIS GND CONNECTOR
CHECK INPUT AND OUTPUT WIRES OF AC
CONTACTOR ARE SECURE
CHECK DC OUTPUT NEGATIVE
CHECK DC OUTPUT POSITIVE
CHECK DC FUSE
CHECK SHUNT RESISTOR
/
Webasto Charging Systems, Inc.
15 AAC @
DATE:
/
DATE:

Advertisement