Table 2 Front Panel LEDs

Quantum SuperLoader 3A Series User's Guide
The functionality of the two front panel LEDs is defined in
Function
Power off
Ready
Normal activity
Autoloader attention
Autoloader error
When you first power on the Quantum SuperLoader 3A, it automatically
runs a Power-on Self-Test (POST). During the POST, the left (
flashes. After the POST, the left (
alternately back and forth. Do one of the following:
• If the autoloader powers on successfully, continue configuring the
autoloader (see
Configuring the
The front panel requires a six-digit password to change the
Note:
configuration (see
LCD front panel default password for the Administrator is
. The default password for the Operator is
000000
• If the autoloader does not power on successfully, check the following:
Power switch is on
Power cable is inserted correctly
No error code displays on the autoloader LCD
• If you cannot resolve the problem, contact your service representative
or go to www.quantum.com.
When you first power on the autoloader, the setting for the Internet
Protocol (IP) address is static with the address
to use Dynamic Host Configuration Protocol (DHCP) to change the IP
address, see
Setting the IP Address
address when using DHCP, view the Ethernet status information.
All the functionality accessed from the scrolling menu can be password-
protected. Two levels of security are built into the menu. The lower-level
Chapter 2 Operating the Autoloader
Green
OFF
ON
Flashing
OFF
OFF
) and right (
Green
Amber
Autoloader).
Setting Passwords
on page 15). The
192.168.20.128
on page 9. To determine the IP
Using the Front Panel
table
2.
Amber
OFF
OFF
OFF
Flashing
ON
) LED
Green
) LEDs flash
.
111111
. If you want