rt

rts

© Polycom, Inc. 2003
ViewStation EX, ViewStation FX, and VS4000 API Guide
rt <normal|inverted|get>
Description
This command lets you configure the rt serial interface control signal
(receive timing: clock). The default setting for this signal is normal.
normal
Sets the signal to normal (rising edge receives data).
inverted
Sets the signal to inverted (falling edge receives data).
get
Displays the current setting for this option (normal or
inverted).
Example
rt inverted
User Interface Screen Location
System Info>Admin Setup>Video Network>Advanced V.35: RT
This screen is only accessible if you have a
V.35/RS-449/RS-530/RS-366 network interface connected to your
system.
rts <normal|inverted|get>
Description
This command lets you configure the rts serial interface control
signal (request to send). The default setting for this signal is normal.
normal
Sets the signal to normal (high voltage is logic 1).
inverted
Sets the signal to inverted (low voltage is logic 1).
get
Displays the current setting (normal or inverted).