Standard
Interface
Isolation
( output to
ground)
Isolation (input
to ground)
Parallel Number
IP
Safety Standard
Cooling
Working
Temperature
Dimension
( mm)
Weight( net)
*1.The voltage/current input is no less than 10%FS (FS indicates the full scope).
*2.The scope of read-back resistance is
(1/(1/R+(1/R)*0.01%+0.08),1/(1/R-(1/R)*0.01%-0.08)).
*3.The voltage/current input is no less than 10%FS.
*4.The load current value is no less than 2% of FS.
*5. Minimum rise time: for 10% ~ 90% of the current rise time.
Parameter
Resistance
Minimum
Rated value
resistance
operating
Setup
Resolution
Resistance
Read Back
Resolution
Setup Accuracy
OVP
OTP
Ether Net, GPIB, USB, RS232
≤16 units (channels) Parallel connection
Voltage
Current
0~1.2A
Power
0~96W
≒50mΩ
Min.
0.03V at 1.2A
voltage
Input
leakage
current
Voltage
Current
0.1mA
Power
Voltage
Current
0.1mA
Power
Voltage
±(0.05%+0.025%FS)
Copyright © Itech Electronic Co., Ltd.
18.5V
95℃
500V/DC/1mA
1.5KV/AC/5mA
IP20
IEC 61010
Air
0~40℃
82mm*183mm*573mm
5 kg
Model: IT8732P+
0.1~18V
0~6A
0.05Ω~10Ω
0.05V at 6A
0.06mA
1mV
0.1mA
10mW
16bit
0.1 mV
0.1mA
10mW
Specifications
85V
0.1~80V
0~60A
0~400W
0.05Ω~7500Ω
≒15mΩ
0.5V at 60A
0.2mA
10mV
1mA
1 mV
1mA
±(0.05%+0.025%F
S)
89