Operations - ITech IT8700P+ Series User Manual

Dc programmable electronic loads
Table of Contents

Advertisement

current accuracy of car chargers, which prevents over-current protection of
car chargers.
The CW+CC mode is often used to UPS battery test, simulate the current
change when the battery voltage is decaying. It can also be used to
simulate the characteristics of the inputs of DC-DC converters and
inverters.

4.3.6 Operations

The following will show you how to set operation mode on front panel. Take CC
mode as an example:
1.
Power on the electronic load
2.
Press
channel 1
CH01 CC OFF
Vdc=0.0000V
Adc=0.0000A
Wdc=0.00W
3.
Press
enter the mode selection menu <Mode>, press
mode CC/CV/CR/CW,such as CC,press
CH01
Mode=CC
RANGE=HIGH
Iset=9.000A
4.
Press
key to enter the mode selection menu <Mode>, press
such as <low range>, press
CH01
▲ ▲
▼ ▼
or
keys to select the channel to be edited, such as
Setup
Setup
key to enter the channel setup menu, press
▼ ▼
key to enter range selection menu <Range>, press
Enter
Copyright © Itech Electronic Co., Ltd.
Operations introduction
▼ ▼
key to select the
Enter
key to confirm.
▼ ▼
key to confirm.
Enter
key to
Enter
key to select,
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

It8700 seriesIt8700p series

Table of Contents