When enable Von LATCH, voltage rise and is higher than the Von loading
voltage, input of electronic load is turned on. When the power supply's
voltage fall and is lower than Von unload value, input won't be turned off.
Von function panel operations
1.
Power on the electronic load
2.
Select a channel, such as channel 1
CH01 CC OFF
Vdc=0.0000V
Adc=0.0000A
Fig 4-10 VON LATCH load's working range
Fig 4-11 VON LATCH load's working range
Copyright © Itech Electronic Co., Ltd.
Operations introduction
56