A Appendices
Parameters
Characters
o2st
Control Output 2 Signal
000
trst
Transfer Output Signal
000
tr-t
Transfer Output Type
000
tr-h
Transfer Output Upper
000
Limit
tr-l
Transfer Output Lower
000
Limit
o1th
Simple Transfer Output
1 Upper Limit
o1tl
Simple Transfer Output
1 Lower Limit
ev-1
Event Input
Assignment 1
ev-2
Event Input
Assignment 2
ev-3
Event Input
Assignment 3
ev-4
Event Input
Assignment 4
ev-5
Event Input
000
Assignment 5
ev-6
Event Input
000
Assignment 6
clfl
Close/Floating
vmsl
Valve Opening Monitor
*7
800
Selection
calb
Motor Calibration
mot
Travel Time
A - 24
Setting (monitor) value
4-20: 4-20 mA
0-20: 0-20 mA
4-20: 4-20 mA
1-5V: 1-5 V
OFF:
OFF
*2
SP:
Set point
SP-M: Ramp set point
PV:
Process value
MV:
MV (heating) (Not supported for
Position-proportional Models.)
CMV: MV (cooling) (Supported only for
heating/cooling control.)
V-M:
Valve opening (Supported only for
Position-proportional Models.)
*3
*3
*4
*4
NONE: None
STOP: RUN/STOP
MANU: Auto/Manual Switch
*5
PRST: Program Start
DRS: Invert Direct/Reverse Operation
RSP: SP Mode Switch (There must be a remote SP
input.)
AT-2: 100% AT Execute/Cancel
*6
AT-1: 40% AT Execute/Cancel
WTPT: Setting Change Enable/Disable
Communications Writing Enable/Disable (Communi-
cations must be supported.)
LAT: Alarm Latch Cancel
MSP0: Multi-SP No. switching bit 0
MSP1: Multi-SP No. switching bit 1
MSP2: Multi-SP No. switching bit 2
Same as Event Input Assignment 1.
Same as Event Input Assignment 1.
Same as Event Input Assignment 1.
Same as Event Input Assignment 1.
Same as Event Input Assignment 1.
FLOT: Floating control
CLOS: Close control
MEAS: Measured opening
ESTM: Estimated opening
OFF or ON
1 to 999
Display
Default
4-20, 0-20
4-20
4-20, 1-5V
4-20
off
OFF
sp
sp-m
pv
mv
c-mv
v-m
*3
*3
*4
*4
none
MSP0
stop
manu
prst
drs
rsp
at-2
at-1
wtpt
cmwt
lat
msp0
msp1
msp2
Same as
STOP
Event Input
Assignment 1.
Same as
NONE
Event Input
Assignment 1.
Same as
NONE
Event Input
Assignment 1.
Same as
NONE
Event Input
Assignment 1.
Same as
NONE
Event Input
Assignment 1.
flot, clos
FLOT
MEAS
MEAS
ESTM
off, on
OFF
30
E5@C Digital Temperature Controllers User's Manual (H174)
Unit
None
None
None
*3
*3
*4
*4
None
None
None
None
None
None
None
None
None
Seconds