Chapter 10 Advanced Features
Timer 3: Not used
No operation is performed at 12:00 p.m. and the unit enters sleep mode at 12:00 a.m.
◦ Example 2:
If running at a current time of 10:00 a.m. Wednesday
Timer 1: Daily 9:00–18:00
Timer 2: Wednesday 10:00–20:00
Timer 3: Not used
On days other than Wednesday, normal operation begins at 9:00 a.m. and the unit enters sleep mode at 6:00
p.m. On Wednesday, the unit enters sleep mode at 8:00 p.m.
◦ Example 3:
If running at a current time of 10:00 a.m. Wednesday
Timer 1: Daily 9:00–18:00
Timer 2: Wednesday 10:00–1:00 a.m. of the next day
Timer 3: Not used
On days other than Wednesday, normal operation begins at 9:00 a.m. and the unit enters sleep mode at 6:00
p.m. On Wednesday, normal operation begins at 10:00 a.m. and the unit enters sleep mode at 1:00 a.m. of
the next day.
◦ Example 4:
If running at a current time of 10:00 a.m. Wednesday
Timer 1: Daily 9:00–18:00
Timer 2: Wednesday 7:30–22:00
Timer 3: Not used
On days other than Wednesday, normal operation begins at 9:00 a.m. and the unit enters sleep mode at 6:00
p.m. On Wednesday, normal operation begins at 7:30 a.m. and the unit enters sleep mode at 10:00 p.m.
• To wake the TeraStation from sleep mode before the wake-up time, press and hold down the power button for
three seconds.

UPS (Uninterruptible Power Supply)

If a UPS (sold separately) is attached, the TeraStation can be automatically shut down to protect data in the event of
a power outage.
The procedure to configure for a UPS device is different depending on how many power supply units are installed
on your TeraStation. Depending on your setup, follow one of the procedures below for your TeraStation.
Notes:
• If the TeraStation is connected directly to a UPS, select "Sync with UPS connected to this TeraStation". If a different
Buffalo NAS device is connected to the UPS, select "Sync with UPS connected to another Buffalo NAS device on
the same network". After making this selection, enter the IP address of the Buffalo NAS device that will be the
sync source into "Other Buffalo NAS's IP Address".
• If you don't want to connect any UPS devices, select "Do not synchronize with UPS" and the operation for if a
power supply failure occurred. If "Use last state" at "AC Power Recovery" is selected, the TeraStation will revert to
the state before the power supply failure occurred. If "Stay off" is selected, the TeraStation will remain off even
after the TeraStation shuts down due to the power supply failure.
• When the TeraStation restarts after an automatic shutdown such as from a power outage or power supply issue,
verify that external power has been restored. If the TeraStation is turned on while it is still running on the UPS and
external power has not been restored, the automatic shutdown will not be performed, even after the specified
time elapses.
• If the power supply from the UPS to the TeraStation stops and restarts when UPS recovery is enabled, the
TeraStation will automatically restart.
244