Chapter 13 Appendix
LCD Message
E30 Replace
Drive x
E32 Check
Power Supply
E41 NVRAM
Failure
E42 Migration
Canceled

Notices

If a non-critical error occurs, one of the following messages will appear on the LCD panel and the info LED will
glow amber. If there is a corresponding corrective action described below for the code, try it first. If the code is still
displayed after trying the corrective action, contact Buffalo technical support for assistance.
You can also confirm the current status from the Dashboard in Settings or by using NAS Navigator2. If NAS
Navigator2 displays the error as an unknown error, check the Dashboard in Settings for the error details.
You can click the "Clear" button to delete messages from the Dashboard.
Note: The "x" in the LCD message is the number of the drive, array, or job involved in the process.
LCD Message
I10 System Is
Overheating
I11 Bad
Sectors on
Drive x
I12 Degraded
Mode
I33
Replication
Failure
I44 Drive 1
Not Found
I45 Recovery
Failure
I49 Lost
Failover Main
I54 Backup
Job x Failure
Description
An error occurred, so the drive was
removed from the RAID array.
Power supply error.
The NVRAM inside the TeraStation failed.
The migration process has been canceled
because an error occurred.
Description
A rise in the system temperature may have
exceeded the allowable safety value.
The drive has too many bad sectors.
Operating in degraded mode.
An error occurred in replication, or
synchronization between the main
TeraStation and the backup TeraStation
failed during failover configuration.
Initialization from the USB initialization
drive was initiated, but the drive in slot 1
was not detected.
Initialization failed.
The main TeraStation in the failover
configuration cannot be found.
The backup job failed.
Corrective Action
Replace the drive. Refer to the appropriate
drive replacement sections in chapter
11 that corresponds to your TeraStation
model.
Make sure that the power cable is securely
connected. If the error is still present,
replace the failed PSU to a new OP-PU-
10R2 unit.
Contact Buffalo technical support for
assistance.
Refer to the
detailed corrective actions.
Corrective Action
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
Replace the drive. Refer to the appropriate
drive replacement sections in chapter
11 that corresponds to your TeraStation
model.
Check if the
it is, refer to the corrective action for the
E30
error.
From Settings, navigate to Backup >
Replication and click Resync to execute
resynchronization.
If you configured the subfolders' access
restrictions to be inherited to the
replication or failover destinations, disable
them or change the destinations.
Make sure that the drive in slot 1 is present
and fully inserted into its slot.
-
Make sure that the main TeraStation is on,
working, and connected to the network.
Refer to the
Fails"
section in chapter 5 and try the
respective corrective actions.
283
NAS migration guide
for the
E30
error is also displayed. If
"Backup Logs for If Backup