Chapter 7 Advanced Features
4
Enable "Wake-on-LAN", then click OK.
Wake-on-LAN is now enabled. As long as the TeraStation is connected to a power source and the network, you can
turn it on remotely.
Notes:
• After receiving the Wake-on-LAN packet, the TeraStation may take up to five minutes to be ready to use.
• To use Wake-on-LAN, you'll need Wake-on-LAN software that sends Wake-on-LAN packets. The TeraStation does
not include Wake-on-LAN software.
• The TeraStation does not support using Wake-on-LAN and port trunking at the same time. You may use either
feature, but not both at the same time.

UPS (Uninterruptible Power Supply)

If a UPS (sold separately) is attached, the TeraStation can be automatically shut down to protect data in the event of
a power outage.
Notes:
• If the TeraStation is connected directly to a UPS, select "Sync with UPS connected to this TeraStation". If a different
Buffalo NAS device is connected to the UPS, select "Sync with UPS connected to another Buffalo NAS device on
the same network". After making this selection, enter the IP address of the Buffalo NAS device that will be the
sync source into "Other Buffalo NAS's IP Address".
• If you don't want to connect any UPS devices, select "Do not synchronize with UPS" and the operation for if a
power supply failure occurred. If "Use last state" at "AC Power Recovery" is selected, the TeraStation will revert to
the state before the power supply failure occurred. If "Stay off" is selected, the TeraStation will remain off even
after the TeraStation shuts down due to the power supply failure.
• When the TeraStation restarts after an automatic shutdown such as from a power outage or power supply issue,
verify that external power has been restored. If the TeraStation is turned on while it is still running on the UPS and
external power has not been restored, the automatic shutdown will not be performed, even after the specified
time elapses.
• If the power supply from the UPS to the TeraStation stops and restarts when UPS recovery is enabled, the
TeraStation will automatically restart.
1
Plug the power cable of the UPS to a wall socket.
2
Connect the power cable of the TeraStation to the UPS.