7 Tag Data Link Functions

7-2-13 Clearing the Device Parameters

You can clear the tag data link settings (or return them to their factory settings) that are saved in the
registered EtherNet/IP device. The following procedure shows how to clear the tag data link settings.
For details on how to connect to the network from the Network Configurator, refer to 7-2-8 Connecting
the Network Configurator to the Network.
Precautions for Correct Use
Precautions for Correct Use
For a CPU Unit with Unit Version 1.10 or Later
• Use the Network Configurator version 3.58 or higher to perform the following procedures to
clear the tag data link settings.
• If you perform the following procedures from the Network Configurator version 3.57 or lower,
the tag data link settings are not cleared. Refer to Additional Information in this section for the
procedures to clear the tag data link settings from the Network Configurator version 3.57 or
lower.
1
Connect the Network Configurator online.
2
Select the icon of the device from which you want to clear the device parameters. In the follow-
ing example, 2 nodes are selected: 192.168.250.1 and 192.168.250.2. To select multiple nodes,
press and hold the Shift Key while you select additional icons.
3
Select Device - Reset. You can also right-click the icon and select Reset from the popup menu.
4
The following dialog box is displayed.
7-72
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)