– Disconnect fuel line -arrow- by pressing release button.
– Lay aside right locking flange with auxiliary heater intake lines
connected.
Note
Ignore items -1 to 4-.
– Grasp in fuel tank opening and remove Fuel Level Sensor - G-
through guide in direction of -arrow 2- while pressing locking
tab -arrow 1-.
Note
Fuel Level Sensor - G- is shown without fuel tank to provide a
better illustration.
Installing
Tightening specification. Refer to
⇒ "2.1 Overview - Fuel Delivery Unit and Fuel Gauge Sensor",
page 17
.
Install in reverse order of removal. Note the following:
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Note
Replace seal.
– Insert Fuel Level Sensor - G- into guide until it engages audi‐
bly.
– Connect electrical connectors -1 and 2- on underside of right
locking flange.
Fuel Supply System - Edition 10.2018