Fuel Level Sensor 2 G169 , Checking - Audi Q7 2007 Repair Manual

Fuel supply system
Hide thumbs Also See for Q7 2007:
Table of Contents

Advertisement

Audi Q7 2007 ➤
Fuel Supply System - Edition 10.2018
– Install the new locking flange seal dry.
– Bring the right locking flange into the installation position.
Tab -2- on right locking flange faces toward arrow marking and
must lie between tabs -1 and 3- on fuel tank.
– Install locking flange cover.
– Insert the frame into the floor covering. Refer to the Parts Cat‐
alog and ⇒ Body Interior; Rep. Gr. 70 .
– Install the right seat cushion in the second row. Refer to ⇒
Body Interior; Rep. Gr. 72 .
– Be sure to follow the procedure for connecting the battery and
afterwards. Refer to ⇒ Electrical Equipment; Rep. Gr. 27 .
Vehicles with Auxiliary Heater:
– Allow to run 10 minutes at full throttle to bleed fuel supply line
to auxiliary heater metering pump.
2.12
Fuel Level Sensor 2 - G169- , Checking
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
Special tools and workshop equipment required
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
♦ Analog/Digital Multimeter - VAG1526D-
♦ Connector Test Set - VAG1594C-
Procedure
– Remove the left seat cushion in the second row. Refer to ⇒
Body Interior; Rep. Gr. 72 .
WARNING
Risk of injury.
♦ Wear safety gloves.
– Cut the floor covering along the perforation -arrows- on the left
side with a carpet knife -1-.
46
Rep. Gr.20 - Fuel Supply
with respect to the correctness of information in this document. Copyright by AUDI AG.

Advertisement