Audi Q7 2007 Repair Manual page 33

Fuel supply system
Hide thumbs Also See for Q7 2007:
Table of Contents

Advertisement

– Press the floor covering to the side and disconnect the con‐
nector -1-.
Note
Ignore -arrows-.
All Vehicles
– Connect connector terminal -2- with an adapter cable from
Connector Test Set - VAG1594C- to chassis Ground (GND).
– Connect Injection Rate Comparison Meter Kit - Remote Cable
- VAG1348/3A- with Injection Rate Kit - Remote Cable -
VAG1348/3-3- to terminal -1- on connector.
– Cover the second connector terminal of Injection Rate Kit -
Remote Cable - VAG1348/3-3- with insulating tape to prevent
short circuit -arrow-.
– Route Injection Rate Comparison Meter Kit - Remote Cable -
VAG1348/3A- switch forward in engine compartment.
– Release the retaining clip and open the cover -A- over the
positive terminal clamp.
– Connect the alligator clip to the positive terminal clamp.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
– Remove the fuel cap from the fuel filler tube.
with respect to the correctness of information in this document. Copyright by AUDI AG.
WARNING
Risk of injury from fuel.
♦ To reduce residual pressure remaining in fuel system, lay
a clean cloth around the connector and carefully loosen
connector.
– Disconnect fuel line -2-.
Note
Ignore item -1-.
Fuel Supply System - Edition 10.2018
2. Fuel Pump, Fuel Delivery Unit and Fuel Level Sensor
Audi Q7 2007 ➤
29

Advertisement

Table of Contents
loading