Fuel Tank, Draining - Audi Q7 2007 Repair Manual

Fuel supply system
Hide thumbs Also See for Q7 2007:
Table of Contents

Advertisement

Fuel Tank, Tightening Specifications and Sequence
– Tighten the bolts in 3 steps as follows:
Stage
Bolts
1.
-9, 10, 11, and 12-33 Nm
2.
-1, 4, 5, and 8- 33 Nm
3.
-2, 3, 6, and 7- 33 Nm
Fuel Pump Control Module - J538- for Vehicles from 11.2006 -
Tightening Specifications
Installed location: on the right side of the underbody, under the
rear seat bench and under the floor covering
– Tighten nuts -arrows- to 3.5 Nm.
Installation Position of Ground (GND) Connection
– Route Ground (GND) connection -2- as shown in illustration.
– Engage ground wire on EVAP canister -arrow-.
– Ensure connector of Ground (GND) connection fits securely
at metal ring -1- of fuel filler tube.
WARNING
Risk of explosion due to electrostatic charge.
♦ After Installation, check electrical connection on fuel filler
neck metal ring to an empty spot on the body using an
Ohm meter.
• Specified value: approximately 0 Ω.
1.2

Fuel Tank, Draining

Special tools and workshop equipment required
♦ Wrench - Fuel Sending Unit - T10202-
♦ Fuel Extraction Unit - VAS5190-
Tightening Specification
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Audi Q7 2007 ➤
Fuel Supply System - Edition 10.2018
1. Fuel Tank with Attachments