ZyXEL Communications XMG1930-30 User Manual page 199

30-port multi-gigabit smart managed layer-2 switch, 30-port multi-gigabit smart managed layer-2 poe switch
Table of Contents

Advertisement

Table 87 SNMP System Traps
OPTION
OBJECT LABEL
coldstart
coldStart
warmstart
warmStart
fanspeed
zyHwMonitorFanSpeedOutOfR
ange
zyHwMonitorFANSpeedOutOfR
angeRecovered
temperature
zyHwMonitorTemperatureOut
OfRange
zyHwMonitorTemperatureOut
OfRangeRecovered
voltage
zyHwMonitorPowerSupplyVolt
ageOutOfRange
reset
zySysMgmtUncontrolledSystem
Reset
zySysMgmtControlledSystemR
eset
zySysMgmtBootImageInconsist
ence
RebootEvent
timesync
zyDateTimeTrapTimeServerNot
Reachable
zyDateTimeTrapTimeServerNot
ReachableRecovered
loopguard
zyLoopGuardLoopDetect
errdisable
zyErrdisableDetect
zyErrdisableRecovery
Chapter 26 SNMP
OBJECT ID
1.3.6.1.6.3.1.1.5.1
1.3.6.1.6.3.1.1.5.2
1.3.6.1.4.1.890.1.15
.3.26.2.1
1.3.6.1.4.1.890.1.15
.3.26.2.6
1.3.6.1.4.1.890.1.15
.3.26.2.2
1.3.6.1.4.1.890.1.15
.3.26.2.7
1.3.6.1.4.1.890.1.15
.3.26.2.3
1.3.6.1.4.1.890.1.15
.3.49.2.1
1.3.6.1.4.1.890.1.15
.3.49.2.2
1.3.6.1.4.1.890.1.15
.3.49.2.3
1.3.6.1.4.1.890.1.5.
1.1.2
1.3.6.1.4.1.890.1.15
.3.82.3.1
1.3.6.1.4.1.890.1.15
.3.82.3.2
1.3.6.1.4.1.890.1.15
.3.45.2.1
1.3.6.1.4.1.890.1.15
.3.24.4.1
1.3.6.1.4.1.890.1.15
.3.24.4.2
XMG1930 Series User's Guide
199
DESCRIPTION
This trap is sent when the Switch is turned on.
This trap is sent when the Switch restarts.
This trap is sent when the fan speed goes
above or below the normal operating
range.
This trap is sent when the fan speed is
recovered from the out of range to normal
operating range.
This trap is sent when the temperature goes
above or below the normal operating
range.
This trap is sent when the temperature is
recovered from the out of range to normal
operating range.
This trap is sent when the voltage goes
above or below the normal operating
range.
This trap is sent when the Switch
automatically resets.
This trap is sent when the Switch resets by an
administrator through a management
interface.
This trap is sent when the index number of
image which is loaded when the Switch
starts up is different from what is specified
through the CLI.
This trap is sent when the Switch reboots by
an administrator through a management
interface.
This trap is sent when the Switch's date and
time is not manually entered or the specified
time server is not reachable.
This trap is sent when the Switch's real time
clock is up to date.
This trap is sent when loopguard shuts down
a port.
This trap is sent when an error is detected on
a port, such as a loop occurs or the rate limit
for specific control packets is exceeded.
This trap is sent when the Switch ceases the
action taken on a port, such as shutting
down the port or discarding packets on the
port, after the specified recovery interval.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xmg1930 series

Table of Contents