YASKAWA iC9200 Series Manual page 103

Cpu
Hide thumbs Also See for iC9200 Series:
Table of Contents

Advertisement

iC9200 Series
Enable or disable Syslog
configuration
4.9.5.5
User Authentication
HB700 | CPU | PMC921xEx | en | 23-06
3.
Specify the following parameters at Filter Options:
n
Facilities
Here you specify the system type of the log data.
n
Severity Level
Determine here the severity level from which the log data is sent to the
Syslog server.
Level 1: >= Internal (debug): All messages are sent.
Level 2: >= Information (info): Messages >= level 2 are sent.
Level 3: >= Warning (warning): Messages >= level 3 are sent.
Level 4: >= Error (err): Messages >= level 4 are sent.
Level 5: >= Critical Error (crit): Messages >= level 5 are sent.
Level 6: >= Fatal Error (alert): Messages >= level 6 are sent.
Level 7: Emergency (emerg) Only emergency messages are sent.
4.
Click at [OK].
ð The dialog is closed and the Syslog server is listed in the table.
You can remove entries with
Security
iC92...
PMC92...
Syslog Configuration
Information
Diagnostics
Configuration
Security
Certificate Authentication
Firewall
SD Card
Syslog Configuration
User Authentication
Administration
1.
By selecting or deselecting the control field of 'Syslog Server Destination
Activation' at 'Syslog Configuration' you can enable respectively disable the Syslog
server targets specified in the table.
2.
Click on [Apply].
ð The settings are accepted.
n
At 'User Authentication' you can enable or disable user authentication.
n
If user authentication is enabled, you have access to definable components of the
CPU and functions in iCube Engineer exclusively by specifying user name and pass-
word.
n
If user authentication is disabled, access takes place without a user query. The areas
for the administrator remain password-protected.
Web-based management - WBM > Security
and edit them with
.
Deployment
103

Advertisement

Table of Contents
loading

Table of Contents