Rear Drive Module; Removing The 2 X 2.5-Inch Rear Drive Module - Dell PowerEdge R760 Installation And Service Manual

Table of Contents

Advertisement

Figure 61. Installing a drive into the drive carrier
Next steps
1.
Install the drive
carrier.

Rear drive module

Removing the 2 x 2.5-inch rear drive module

Prerequisites
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
3. If required,
remove the air
4.
Remove the
drives.
5. Disconnect the cables from the rear drive module.
NOTE:
Refer to
cable routing
Table 76. Rear drive bay slot numbers
Configurations with two rear drives
12 x 3.5-inch SAS/SATA + 2 x 2.5-inch SAS/
SATA
12 x 3.5-inch SAS/SATA + 2 x 2.5-inch NVMe
24 x 2.5-inch SAS/SATA + 2 x 2.5-inch SAS/
SATA
24 x 2.5-inch SAS/SATA + 2 x 2.5-inch NVMe
Steps
1. Using a Phillips #2 screwdriver, loosen the captive screws that secure the rear drive module to the system.
2. Press the blue release tab and holding the edges lift the rear drive module away from the system.
Safety
instructions.
Before working inside your
shroud.
section for more information.
Bay0 slot numbers
Slot 0 and 1
Slot 0 and 1
N/A
Slot 0 and 1
system.
Installing and removing system components
Bay1 slot numbers
N/A
N/A
Slot 24 and 25
N/A
111