Table 65. Serial Communication details (continued)
Option
Serial Port Address
External Serial Connector
Failsafe Baud Rate
Remote Terminal Type
Redirection After Boot
System Profile Settings
To view the System Profile Settings screen, power on the system, press F2, and click System Setup Main Menu > System
BIOS > System Profile Settings.
Table 66. System Profile Settings details
Option
System Profile
CPU Power Management
Description
On with Console Redirection, Off, Auto. This option is set to
Auto by default.
Enables you to set the port address for serial devices. This
option is set to either COM1 or COM2 for the serial device
(COM1=0x3F8,COM2=0x2F8)and set to COM1 by default.
NOTE:
feature. To use console redirection by SOL, configure the same port
address for console redirection and the serial device.
NOTE:
setting that is saved in iDRAC. The serial MUX setting can independently
be changed in iDRAC. Loading the BIOS default settings from within the
BIOS setup utility may not always revert the serial MUX setting to the
default setting of Serial Device 1.
Enables you to associate the External Serial Connector to Serial Device 1,
Serial Device 2, or the Remote Access Device by using this option. This
option is set to Serial Device 1 by default.
NOTE:
To use console redirection by SOL, configure the same port address for
console redirection and the serial device.
NOTE:
setting saved in iDRAC. The serial MUX setting can independently be
changed in iDRAC. Loading the BIOS default settings from within the BIOS
setup utility may not always revert this setting to the default setting of
Serial Device 1.
Specifies the failsafe baud rate for console redirection. The BIOS attempts to
determine the baud rate automatically. This failsafe baud rate is used only if
the attempt fails, and the value must not be changed. This option is set to
115200 by default.
Sets the remote console terminal type. This option is set to VT100/VT220 by
default.
Enables or disables the BIOS console redirection when the operating system is
loaded. This option is set to Enabled by default.
Description
Sets the system profile. If you set the System Profile option to a mode other than
Performance Per Watt (DAPC), the BIOS automatically sets the rest of the options. You
can only change the rest of the options if the mode is set to Custom. This option is set to
Performance Per Watt (DAPC) by default. Other options include Custom, Performance,
Performance Per Watt (OS) and Workstation Performnce.
NOTE:
All the parameters on the system profile setting screen are available only when
the System Profile option is set to Custom.
Sets the CPU power management. This option is set to System DBPM (DAPC) by default.
Other option includes Maximum Performance, OS DBPM.
You can use only Serial Device 2 for the Serial Over LAN (SOL)
Every time the system boots, the BIOS syncs the serial MUX
Only Serial Device 2 can be used for Serial Over LAN (SOL).
Every time the system boots, the BIOS syncs the serial MUX
Pre-operating system management applications