Rear Drive Module; Removing The Rear Drive Module - Dell PowerEdge R6625 Installation And Service Manual

Table of Contents

Advertisement

4. If installed,
Remove the air
5. Route the cable properly to prevent the cable from being pinched or crimped.
Steps
1. Connect the PERC cable to the front PERC module.
2. Align the front PERC module at an angle until the tray touches the slot in the system.
3. Press the front PERC module connector with the connector on the drive backplane until firmly seated.
4. Using a Phillips #2 screwdriver, tighten the captive screws on the front PERC module.
NOTE:
The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 83. Installing the front mounting front PERC module
Next steps
1. Reconnect all the required cables.
2. If removed,
Install the air
3.
Install the drive backplane
4. Follow the procedure listed in

Rear drive module

Removing the rear drive module

Prerequisites
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
3.
Remove the air shroud.
4. Disconnect all the cables from the rear drive module.
5. If installed,
remove the expansion card riser.
106
Installing and removing system components
shroud.
shroud.
cover.
After working inside your
Safety
instructions.
Before working inside your
system.
system.