Dell PowerEdge R760 Installation And Service Manual page 319

Table of Contents

Advertisement

Table 159. Status LED indicators and descriptions (continued)
Icon
Description
Temperature
indicator
Electrical
indicator
Memory indicator
PCIe indicator
Condition
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
The indicator turns solid amber
if the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or
voltage regulator).
The indicator turns solid amber if a
memory error occurs.
The indicator turns solid amber if a
PCIe card experiences an error.
Corrective action
● If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Ensure that none of the following conditions exist:
● A cooling fan has been removed or has failed.
● System cover, air shrouds, or back filler bracket
has been removed.
● Ambient temperature is too high.
● External airflow is obstructed.
If the problem persists, see the
Check the System Event Log or system messages
for the specific issue. If it is due to a problem with
the PSU, check the LED on the PSU. Reseat the
PSU.
If the problem persists, see the
Check the System Event Log or system messages
for the location of the failed memory. Reseat the
memory module.
If the problem persists, see the
Restart the system. Update any required drivers for
the PCIe card. Reinstall the card.
If the problem persists, see the
NOTE:
For more information about the
supported PCIe cards, see the
and expansion card risers
installation guidelines section.
System diagnostics and indicator codes
Getting help
section.
Getting help
section.
Getting help
section.
Getting help
section.