Dell PowerEdge R760 Installation And Service Manual page 167

Table of Contents

Advertisement

Figure 121. Configuration 45: 16 x 2.5-inch (8 x SAS/SATA with fPERC (HBA355i, H355, H755) + 8 x NVMe RAID
with fPERC (H965i))
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 124. 16 x 2.5-inch (8 x SAS/SATA with fPERC (HBA355i, H355, H755) + 8 x NVMe RAID with fPERC
(H965i))
Order
1
2
3
4
5
6
7
NOTE:
An 8 x 2.5-inch NVMe backplane with fPERC H965i should be assembled outside and inserted into the system,
along with all necessary cables.
From
SIG_PWR_1 (system board power connector)
SL3_CPU1_PA2 (signal connector on system
board)
SIG_PWR_2 (system board power connector)
CTRL_SRC_PB1 (fPERC controller connector)
CTRL_SRC_PA1 (fPERC controller connector)
SL7_CPU1_PB4 (signal connector on system
board)
SL8_CPU1_PA4 (signal connector on system
board)
To
BP_PWR_1 (backplane power connector)
CTRL_DST_PA1 (fPERC input connector)
BP_PWR_2 (backplane power connector)
BP_DST_PA2 (backplane signal connector)
and BP_DST_PB2 (backplane signal
connector)
BP_DST_PA1 (backplane signal connector)
and BP_DST_PB1 (backplane signal
connector)
CTRL_DST_PA1 (fPERC input connector)
CTRL_DST_PB1 (fPERC input connector)
Installing and removing system components
167