Video specifications

The PowerEdge R760 system supports integrated Matrox G200 graphics controller with 16 MB of video frame buffer.
Table 21. Supported video resolution options
Resolution
1024 x 768
1280 x 800
1280 x 1024
1360 x 768
1440 x 900
1600 x 900
1600 x 1200
1680 x 1050
1920 x 1080
1920 x 1200

Environmental specifications

NOTE:
For additional information about environmental certifications, refer to the Product Environmental Datasheet located
with the Documentation on www.dell.com/support/home.
Table 22. Continuous Operation Specifications for ASHRAE A2
Temperature
Allowable continuous operations
Temperature range for
altitudes <= 900 m (<=
2953 ft)
Humidity percent range
(non-condensing at all
times)
Operational altitude de-
rating
Table 23. Continuous Operation Specifications for ASHRAE A3
Temperature
Allowable continuous operations
Temperature range for
altitudes <= 900 m (<=
2953 ft)
Humidity percent range
(non-condensing at all
times)
Operational altitude de-
rating
38
Technical specifications
Refresh rate (Hz)
60
60
60
60
60
60
60
60
60
60
Specifications
10–35°C (50–95°F) with no direct sunlight on the equipment
8% RH with -12°C (10.4°F) minimum dew point to 80% RH with 21°C (69.8°F) maximum dew
point
Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
Specifications
5–40°C (41–104°F) with no direct sunlight on the equipment
Excursion Limited Operation
8% RH with -12°C (10.4°F) minimum dew point to 85% RH with 24°C (75.2°F) maximum dew
point
Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft)
Color depth (bits)
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
8, 16, 32
5-35°C (41-95°F) Continuous Operation
35-40°C (95-104°F) 10% Annual Runtime