Dell PowerEdge R760 Installation And Service Manual page 135

Table of Contents

Advertisement

Figure 88. Configuration 12: 16 x 2.5-inch NVMe RAID with fPERC (H755N)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 91. 16 x 2.5-inch NVMe RAID with fPERC (H755N)
Order
1
2
3
4
5
6
7
8
NOTE:
An 8 x 2.5-inch NVMe backplanes with fPERC H755 should be assembled outside and inserted into the system,
along with all necessary cables.
From
SL1_CPU2_PA1 (signal connector on
system board)
SIG_PWR_1 (system board power
connector)
CTRL_SRC_PB1 (fPERC controller
connector)
CTRL_SRC_PA1 (fPERC controller
connector)
SL3_CPU1_PA2 (signal connector on
system board)
SIG_PWR_2 (system board power
connector)
CTRL_SRC_PB1 (fPERC controller
connector)
CTRL_SRC_PA1 (fPERC controller
connector)
To
CTRL_DST_PA1 (fPERC input connector)
BP_PWR_1 (backplane power connector)
BP_DST_PA2 (backplane signal connector) and
BP_DST_PB2 (backplane signal connector)
BP_DST_PA1 (backplane signal connector) and
BP_DST_PB1 (backplane signal connector)
CTRL_DST_PA1 (fPERC input connector)
BP_PWR_1 (backplane power connector)
BP_DST_PA2 (backplane signal connector) and
BP_DST_PB2 (backplane signal connector)
BP_DST_PA1 (backplane signal connector) and
BP_DST_PB1 (backplane signal connector)
Installing and removing system components
135

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E82s

Table of Contents