Bay Networks 5393 Hardware Installation Manual page 61

Remote annex
Hide thumbs Also See for 5393:
Table of Contents

Advertisement

To initialize the Remote Annex and enter Monitor Mode:
1
Use a terminal connected to the chassis service port to verify that
the Remote Annex is operating properly.
The Slot Selection menu is displayed. The Remote Annex should
be listed next to the slot number in which it is installed. Since the
module occupies two slot positions, the slot number listed will
be that of the right-most slot being occupied.
2
Reset the Remote Annex by typing r and then entering the slot
number of the chassis that contains the server.
The following prompt is displayed:
Are you sure you want to RESET this module? (Y/N):
3
Answer the question by entering y.
4
Within 10 seconds, connect to the Remote Annex by typing c and
then entering the slot number of the chassis that contains the server.
5
Wait for the following prompt:
To enter "Monitor Mode" please depress the SPACE key
within 10 seconds.
The prompt counts down from 10 seconds.
6
Press the space bar within 10 seconds.
After a few seconds, the following messages are displayed:
Monitor Mode selected, please wait for Confidence tests
to complete.
System Reset - Entering Monitor Mode
Then the monitor prompt is displayed:
monitor::
To return to the Slot Selection menu from Monitor Mode, press
the
key.
Break
Remote Annex 5393/PRI Hardware Installation Guide
Chapter 2
Installing the Remote Annex 5393/PRI