Table 4-3. Errors From Last Erpc Layer Invocation; Table 4-4. Errors From Last Read Request - Bay Networks 5393 Hardware Installation Manual

Remote annex
Hide thumbs Also See for 5393:
Table of Contents

Advertisement

Chapter 4
Troubleshooting Procedures
4-10
Remote Annex 5393/PRI Hardware Installation Guide

Table 4-3. Errors from Last ERPC Layer Invocation

Error
Description
H/W errors
The Remote Annex sensed a hardware error during
message transmission or reception. This error indicates a
fault with the Remote Annex LAN interface. Use the net
command to isolate the problem (see net on page 3-18).
Msgs from
The Remote Annex received a message from an incorrect
wrong host
host. This indicates that the Remote Annex received, and
ignored, an unsolicited packet.
Rsp T/O's
The Remote Annex never received a correctly formatted
response from the correct host, or any response from any
load server hosts.
Msgs of
The correct host sent a message to the Remote Annex,
wrong type
but the message was not a correctly formatted response
to the transmitted request.

Table 4-4. Errors from Last Read Request

Error
Msgs with wrong
size
ERPC layer errors
Aborts rx'd
Description
The correct host responded to the Read Request,
but the data size is incorrect.
See
Table
4-3.
The host's BFS transmitted an abort in response to
the Remote Annex's Read Request. Run erpcd –D
on the host to obtain more information.