Figure 2-1. Main Logic Module Jumper And Connector Locations - Bay Networks 5393 Hardware Installation Manual

Remote annex
Hide thumbs Also See for 5393:
Table of Contents

Advertisement

Chapter 2
Installing the Remote Annex 5393/PRI
2-4
Remote Annex 5393/PRI Hardware Installation Guide
DIP
Switch
1
S1

Figure 2-1. Main Logic Module Jumper and Connector Locations

Ethernet Segment Bank Selector
The Ethernet segment bank selector on the Main Logic Module (see
Figure
2-1), consisting of three rows of 20 pins (J6) and a jumper,
determines whether the module connects to Ethernet segments 1
through 6 or segments 7 through 12 at power up. When the jumper
is installed between the bottom and middle rows of pins, the module
has access to segments 1 through 6 (the factory default setting); when
the jumper is installed between the top and middle rows of pins, the
module has access to segments 7 through 12.