Use boot –l only when reloading your Flash memory. Typically,
you reload your Flash memory when you are upgrading to a
new version of software.
The boot –v command displays the boot in verbose mode. This output
includes the turnaround time in milliseconds for each request. This
value equals the time lapse between sending the request and receiving
the proper reply from the host.
When the boot is complete, verbose output includes a display of
network statistics:
monitor:: boot –v
Enter boot file name [(ip) "oper.63.enet", \
(mop) "OPER_63_ENET.SYS"]::
Requesting default boot file "OPER_63_ENET.SYS" for MOP/VMS\
loads and "oper.63.enet" for all other protocols.
Unanswered requests shown as '?', transmission errors as '*'.
Requesting boot from 192.9.200.88 via Ethernet...
Booting from 192.9.200.88 (42 msec)
Header received OK.
turnaround time.
4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 4 4 4 4 4 4 4 4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 5 4 4 4 4 4 4
4 4 4 4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 4 4 4 4 4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 24 4 4 6 4 10 4 6 4 4 4 4
73 4 4 5 4 4 4 4 4 9 4 4 11 4 4 4 4 4 4 4 4 4 4 4 4 4 3 4 4 4 4 4 4 5 4 4
4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 11 6 4 4 4 4 4 4 5 4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 4 4 5
4 4 4 4 4 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 4 4 4 4 4 4
4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 EOF
Ethernet Statistics
Frames Received:
CRC Errors:
Alignment Errors:
Resource Drops:
Bus Wait Drops:
Bad Types/Lengths: 0
Received data blocks shown as msec
1031
Frames Sent:
0
Carrier Sense Losses:
0
Clear to Send Losses:
9
Collisions Detected:
0
Excessive Collision Losses: 0
Remote Annex 5393/PRI Hardware Installation Guide
Chapter 3
ROM Monitor Commands
1031
0
0
9
3-11