Chapter 2
Installing the Remote Annex 5393/PRI
2-6
Remote Annex 5393/PRI Hardware Installation Guide
Table 2-2. Segment Selection DIP Switch Settings
Position
1, 7 (default setting)
2, 8
3, 9
4, 10
5, 11
6, 12
Network management software can override this DIP switch
setting, so an installed module may connect to a different
segment (within the segment bank) than is indicated by the
DIP switch setting.
Installing the Module into the Hub
To install and secure the module into the System 5000 Hub, follow
these steps:
1
Remove the blank filler panel(s) from the chassis slot(s) where you
intend to install the module (two slots needed if equipped with a
Modem Module).
2
Verify that the module jumpers are set correctly (see
Backplane Ethernet Segment
3
Extend the inserter/extractor levers to their fully extended positions
(see
Figure
2-2).
Segment Bank 1-6
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
on page 2-3).
Segment Bank 7-12
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
Segment 12
Setting the