94 Chapter 8 Replacing basic chassis components
3
4
5
6
7

Setting jumpers on the alarm board

The jumpers on the alarm board enable or disable sensing and display
functions. This section describes the features that are enabled or disabled
by setting jumpers on the alarm board.
Copyright © 2007, Nortel Networks
.
Alarm board carrier
Pull the carrier free from the chassis (see B in
(page
94)).
The alarm board is secured to the carrier by two Phillips-head
screws. Remove the defective alarm board from the carrier.
Secure the replacement alarm board to the carrier using two
Phillips-head screws.
Align the carrier with the chassis and slide the board into the chassis.
Note: The card encounters some resistance as it meets the
connector.
Tighten the thumbscrews to secure the faceplate to the chassis.
Nortel CallPilot
1002rp Server Maintenance and Diagnostics
NN44200-701 01.02 Standard
5.0 4 April 2007
—End—