Hard drive bay
5
6 (far right)
a. RAID pairs (logical drives) consist of the following pairs: hard drives 1 and
4,2 and 5, and 3 and 6. these pairs are represented in the software with the
lables A01-01 and A01-02, A02-01 and A02-02, and A03-02, A03-02 where the
first number is the logical drive number (for example, A03) and the second
number indicates if it is the primary or secondary hard drive (01 for primary
and 02 for secondary)
To replace hot-pluggable SCA SCSI hard drives
Step
1
2
3
4
Copyright © 2007, Nortel Networks
.
SCSI
channel
1
1
Action
CAUTION
Risk of equipment damage
Use an ESD wrist strap to protect static-sensitive components.
Ensure the new hard drive has the SCSI ID set to 0, termination
disabled, and parity checking enabled.
Open the front bezel doors.
Locate the SCA SCSI drive frame below a cooling fan and beside
the media drive.
Loosen the two thumbscrews on the carrier of the faulty hard drive,
and remove the carrier from the chassis.
Nortel CallPilot
1002rp Server Maintenance and Diagnostics
NN44200-701 01.02 Standard
5.0 4 April 2007
Replacing a faulty hard drive 101
SCSI ID
Logical drive label
1
A02-02 (secondary hard drive)
2
A03-02 (secondary hard drive)