100 Chapter 9 Replacing media drives
The following image shows a failed drive highlighted in red with the
corresponding logical drive highlighted in yellow (degraded mode)
Failed hard drive displayed in red
RAID SCSI hard drive configuration
"RAID SCSI hard drive configurations" (page 100)
bay, channel, and ID configurations in the hot-swappable drive bay. The
SCSI backplane assigns the SCSI IDs as shown.
RAID SCSI hard drive configurations
Hard drive bay
1 (far left)
2
3
4
a. RAID pairs (logical drives) consist of the following pairs: hard drives 1 and
4,2 and 5, and 3 and 6. these pairs are represented in the software with the
lables A01-01 and A01-02, A02-01 and A02-02, and A03-02, A03-02 where the
first number is the logical drive number (for example, A03) and the second
number indicates if it is the primary or secondary hard drive (01 for primary
and 02 for secondary)
Copyright © 2007, Nortel Networks
.
SCSI
channel
0
0
0
1
Nortel CallPilot
1002rp Server Maintenance and Diagnostics
NN44200-701 01.02 Standard
5.0 4 April 2007
shows proper SCSI drive
SCSI ID
Logical drive label
0
A01-01 (primary hard drive)
1
A02-01 (primary hard drive)
2
A03-01 (primary hard drive)
0
A01-02 (secondary hard drive)