CONNECTION OF THE POWER UNIT
5.2.5 Connection of the motor
5.2.5.1 Wiring of the motor
X1C
Legend
1
KEB COMBIVERT
Apply motor cable, shielding on both sides over a large surface on the bare metallic frame or mounting
2
plate (remove paint if necessary)
3
Three-phase motor
4
Temperature monitoring (optional) =>
Figure 22:
Wiring of the motor
60
➀
➁
Control
P A/K
9
5
10
6
U
X1A
V
W
Instructions for use "Control unit"
➂
➃
U
V
W