DEVICE DATA OF THE PEAK POWER DEVICES
3.2 Device data of the Peak Power devices
3.2.1 Overview of the Peak Power devices
The technical data are for 2/4-pole standard motors. With other pole numbers the drive
controller must be dimensioned onto the rated motor current. Contact KEB for special or
medium frequency motors.
Device size
Housing
Device type
Rated power
Rated apparent output power
Max. rated motor power
Drive controller (input)
Rated input voltage
Input voltage range
Mains phases
Mains frequency
Rated input current
@ U
= 400V
N
Rated input current
@ U
= 480V
N
Insulation resistance @ U
Drive controller (output)
Output voltage
Output frequency
Output phases
Rated output current
@ U
= 400 V
N
Rated output current
@ U
= 480 V
N
Rated output overload (60 s)
Software current limit
Overcurrent
Rated switching frequency
Max. switching frequency
Power dissipation at rated operation
Overload cycle in rated operation
Overload current over time
Maximum current 0Hz / 50Hz at f
Maximum current 0Hz / 50Hz at f
Maximum current 0Hz / 50Hz at f
30
/ kVA
S
out
P
/ kW
1)
mot
/ V
U
N
U
/ V
in
/ Hz
f
N
/ A
I
in
/ A
I
in_UL
= 500V
/ MΩ
R
dc
iso
/ V
U
out
/ Hz
f
2)
out
I
/ A
N
I
/ A
N_UL
I
/ %
3) 4)
60s
/ %
I
3)
lim
/ %
I
3)
OC
f
/ kHz
SN
f
/ kHz
5)
S_max
/ W
P
1)
D
/ %
I
3)
OL
= 2 kHz
I
S
out_max
= 4 kHz
I
S
out_max
= 8 kHz
I
S
out_max
Peak Power
400 (UL: 480)
=> „3.2.3.1 Overload characteristic (OL) for Peak
Power devices"
/ %
/ %
/ %
16
2
22,9
15
280...550
3
50 / 60 ±2
43
35
> 20
0...U
in
0...599
3
33
27
150
190
230
4
8
336
127 / 230
100 / 230
73 / 218
continued on the next page