LS20-B Manipulator 3. Environments and Installation
Connect and disconnect M/C cable
NOTE
In LS20-B series, you can connect and disconnect the M/C cable to/from the Manipulator
easily.
For details, refer to LS-B series Maintenance Manual LS20-B Manipulator 4.3 Replacing
M/C Cable.

3.7 User Wires and Pneumatic Tubes

■ Only authorized or certified personnel should be allowed to perform wiring.
Wiring by unauthorized or uncertified personnel may result in bodily injury and/or
malfunction of the robot system.
CAUTION
User electrical wires and pneumatic tubes are contained in the cable unit.
Electrical Wires
Rated Voltage
AC/DC30V
■ Do not apply the current more than 1A to the manipulator.
WARNING
15 pin
9 pin
Pins with the same number, indicated on the connectors on both ends of
the cables, are connected.
152
Allowable Current
1A
Mfr.
Suitable
DA-15PF-N
Connector
Clamp Hood
DA-C8-J10-F2-1R
JAE
Suitable
DE-9PF-N
Connector
Clamp Hood
DE-C8-J9-F2-1R
Wires
Nominal Sectional Area
15
0.211 mm
9
Standard
(Solder type)
(Connector setscrew : #4-40 NC)
(Solder type)
(Connector setscrew : #4-40 NC)
Note
Twist pair
2
Unshielded