Procedure 3: First-Time Power-Up And Connection To Mcu - Polycom RMX 2000 Getting Started Manual

Hide thumbs Also See for RMX 2000:
Table of Contents

Advertisement

Procedure 3: First-time Power-up and Connection to MCU

2
Modify the following parameters in the utility's dialog box using the
information supplied by your network administrator.
— Control Unit IP Address
— Shelf Management IP Address
— Subnet Mask
— Default Router IP Address
3
Click OK.
To power-up for the first time using the USB key:
1
Insert the USB key containing the modified IP addresses in USB port
on the RMX's back panel.
2
Power the RMX On.
The parameters in the lan.cfg file are uploaded from the USB key to
the RMX's memory and applied during the power-up sequence.
The First-time Power-up is complete when the red ERR LED on the
RMX's front panel remains ON.
This error indication occurs because the Management Network Service
has not been defined prior to the First-time Power-up. The error
indication does not occur on subsequent, (normal) power-ups.