Maintenance – Every 250 operating hours
8.7.5
Checking the oil level in the wheel hubs
Fig. 154
8.7.6
Checking the oil level in the exciter housing
192
NOTICE!
Components may get damaged!
– Use only gear oil of the permitted
specification
'Gear oil SAE 80W-140'
on page 179.
Protective equip-
ment:
1. Move the machine until the oil level inspec-
tion plug is in horizontal position.
2. Park the machine in secured condition
Ä Chapter 6.8 'Parking the machine in
secured condition' on page 133.
3. Clean the area around the level inspection
plug and unscrew the plug.
4. The oil level must reach the bottom edge of
the bore, top up oil if necessary.
5. Turn the level inspection plug tightly back
in.
6. Change the oil in both wheel hubs.
NOTICE!
Components may get damaged!
– Use only gear oil of the permitted
specification
'Gear oil SAE 75W-90'
on page 179.
BW 213 D-5
Ä Chapter 8.3.6
Working clothes
n
Protective gloves
n
Ä Chapter 8.3.5