Maintenance – Every 2000 operating hours
Fig. 196
Fig. 197
226
WARNING!
Danger of burning on hot compo-
nents!
– Wear your personal protective
– Avoid touching hot components.
3. Unscrew the plug.
4. Drain off and collect all hydraulic oil.
5. Turn the plug tightly back in.
We recommend to use our filling
and filtering unit with fine filter to fill
the system. This ensures finest fil-
B-586-0392
tration of the hydraulic oil, prolongs
the lifetime of the hydraulic oil filter
and protects the hydraulic system.
6. Fill in new hydraulic oil.
7. Check the oil level in the inspection glass.
Normal level
Minimum level Middle of inspection glass
8.
B-586-0072
Close the tank with a new cap.
9. Dispose of oil in line with environmental
regulations.