Advertisement

Maintenance – Every 1000 operating hours
Fig. 186
Fig. 187
218
WARNING!
Danger of burning on hot compo-
nents!
– Wear your personal protective
equipment (protective gloves,
protective clothing).
– Avoid touching hot components.
5. Unscrew the drain plug and catch any oil
running out.
6. Turn the drain plug tightly back in.
7. Clean the area around the oil level inspec-
tion plug.
8. Unscrew the oil level inspection plug.
9. Unscrew the oil filler plug and fill in new oil
through the oil filler bore, until oil starts to
drip out through the inspection bore.
10. Retighten the filler and level inspection
plugs.
11. Change the oil on both sides.
12. Dispose of oil in an environmentally friendly
way.