Final Shut-Down Of Machine - Fayat Group BOMAG BW 213 D-5 Operating Instruction

Single drum roller
Hide thumbs Also See for BOMAG BW 213 D-5:
Table of Contents

Advertisement

Disposal – Final shut-down of machine

11.1 Final shut-down of machine

286
After the machine has reached the end of its
service life, the individual components of the
machine must be disposed of properly.
Observe national regulations!
Carry out the following work and have the
machine dismantled by a state-approved recy-
cling company.
WARNING!
Health hazard caused by fuels
and lubricants!
– Safety regulations and environ-
mental protection regulations
must be followed when handling
fuels and lubricants
3.4 'Handling fuels and lubri-
cants' on page 32.
Protective equip-
ment:
1. Remove the batteries.
2. Empty the fuel tank.
3. Drain the hydraulic oil tank.
4. Drain the coolant from the cooling system
and engine.
5. Drain off engine oil.
6. Drain off gear oil.
BW 213 D-5
Ä Chapter
Working clothes
n
Safety shoes
n
Protective gloves
n
Safety goggles
n