6.12.3 Disconnecting the battery
Fig. 120
6.12.4 Emergency exit
Fig. 121
6.12.5 Towing the machine
Operation – Emergency procedures
1. In events of emergency, e.g. in case of a
cable fire, disconnect the battery from the
vehicle network. For this purpose turn the
main battery switch anticlockwise and pull
it out or pull the battery terminal off the bat-
tery.
If a machine has turned over and the cabin
door is jammed, the cabin windows can be
used as emergency exits.
1. Take the emergency hammer out of its
bracket and smash the cabin window.
Tow the machine only in case of emergency or
to prevent an accident.
Towing distance max. 500 m (1600 ft), towing
speed max. 1 km/h (55 ft/min).
Before towing make sure that:
the tractor vehicle has sufficient traction and
n
braking power for the non-braking towed
load;
lifting tackle is of sufficient strength to with-
n
stand the load and is fastened at the points
provided for this purpose.
BW 213 D-5