10.2 Starting the engine with jump leads

Fig. 277
Troubleshooting – Starting the engine with jump leads
1. Connect the plus pole of the external bat-
2. Then connect the second battery cable first
3. Start the engine
4. Once the engine is running switch on a
5. After starting disconnect the negative poles
6. Switch off the consumer.
BW 213 D-5
NOTICE!
A wrong connection will cause
severe damage in the electric
system.
– Bridge the machine only with a
12 Volt auxiliary battery.
tery first with the plus pole of the vehicle
battery using the first jump lead.
to the minus pole of the current supplying
auxiliary battery and then to engine or
chassis ground, as far away from the bat-
tery as possible.
the engine' on page 116.
NOTICE!
Danger of damage to the elec-
tronic system!
If no powerful consuming device is
switched on, voltage peaks may
occur when separating the con-
necting cables between the bat-
teries, which could damage elec-
trical components.
powerful consumer (working light, etc.).