Every 4000 Operating Hours; Replace Ribbed V-Belt And Idler Pulley - Fayat Group BOMAG BW 213 D-5 Operating Instruction

Single drum roller
Hide thumbs Also See for BOMAG BW 213 D-5:
Table of Contents

Advertisement

8.11 Every 4000 operating hours

8.11.1

Replace ribbed V-belt and idler pulley

Fig. 203
Fig. 204
Maintenance – Every 4000 operating hours
Protective equip-
ment:
1. Park the machine in secured condition
Ä Chapter 6.8 'Parking the machine in
secured condition' on page 133.
2. Allow the engine to cool down.
3. Remove the air conditioning compressor V-
belt
conditioning compressor V-belts'
on page 210.
4. Swing the idler pulley back and fixate it by
inserting a locking pin into the fixing hole.
5. Take the ribbed V-belt off the smallest
pulley first.
6. Unscrew fastening screw and take off the
idler pulley.
7. Attach the new idler pulley and tighten the
B-DEU-0020
fastening screw; tightening torque of
80 Nm (59 ft·lbf).
8. Install the new ribbed V-belt.
9. Pull the locking pin out of the fixing hole
and slowly release the idler pulley.
10. Check the correct seat of the ribbed V-belt
on the V-belt pulleys.
11. Install the air conditioning compressor V-
belt
conditioning compressor V-belts'
on page 210.
BW 213 D-5
n
n
Ä Chapter 8.9.2 'Replacing the air
Ä Chapter 8.9.2 'Replacing the air
Working clothes
Protective gloves
231

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents