Parameter
Working
Temperature
Dimension ( mm)
Weight( net)
*1. The instrument needs to be customized under other AC input voltage
ranges. For models equipped with an emergency stop module (including AC
contactor), the AC input voltage range can only be: 342V~528V.
7.1.11 IT6012B-800-50
Source Mode
Rated value ( 0 ℃-50 ℃)
Line Regulation
±(%of Output+Offset)
Load Regulation
±(%of Output+Offset)
Setup Resolution
Read Back Resolution
Setup Accuracy (within 12
months, 25℃ ±5℃) ±(%
ofOutput+Offset)
483mm(W)*801.61mm(D)*151.3mm(H)
Parameter
Output Voltage
Output Current
Output Power
Output Resistance
Voltage
Current
Voltage
Current
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Copyright © Itech Electronic Co., Ltd.
Technical Specification
IT6006B-800-25
0~50℃
20KG
IT6012B-800-50
0~800V
-50~50A
-12~12kW
0~1Ω
≤0.01%FS
≤0.05%FS
≤0.02%S
≤0.05%FS
0.01V
0.01A
0.001kW
0.001Ω
0.01V
0.01A
0.001kW
0.001Ω
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.5% + 0.5%FS
≤1% + 1%FS
270