Parameter
Setup Stability-30min
±(%of Output+Offset)
Setup stability-8h
±(%of Output+Offset)
Readback Stability-30min
±(%of Output+Offset)
Readback stability-8h
±(%of Output+Offset)
Efficiency
Remote Sense Compensa-
tion Voltage
Command Response Time
Power Factor
Storage Temperature
Protective Function
Standard Interface
Isolation ( output to ground)
Working Temperature
Dimension ( mm)
Weight( net)
Note: 1. The instrument needs to be customized under other AC input voltage ranges. For mod-
els equipped with an emergency stop module (including AC contactor), the AC input voltage
range can only be: 342V~528V
Load Mode:
Parameter
Rated value ( 0
℃-50 ℃)
Maximum Input
Current
Maximum Input Ap-
parent Power
Frequency
Voltage
Current
Voltage
Current
Voltage
Current
Voltage
Current
OVP, OCP, OPP, UVP, UCP, OTP, Vsense protection
Standard: USB, CAN, LAN, VCP; optional: GPIB, analog card (in-
cludes RS232), fiber optic socket
483mm(W)*801.61mm(D)*151.3mm(H)
Input voltage
Input current
Copyright © Itech Electronic Co., Ltd.
Technical Specification
IT6018B-500-120
33.37A
19.8kVA
47Hz~63Hz
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
~92%
≤5V
2mS
0.99
-10℃~70℃
1000V
0~50℃
40KG
IT6018B-500-120
0~500V
0~120A
263