ITech IT6000B Series User Manual page 259

Regenerative power system
Hide thumbs Also See for IT6000B Series:
Table of Contents

Advertisement

Parameter
Setup Accuracy
(within 12 months,
25℃ ±5℃) ±(%
ofOutput+Offset)
Read Back Accu-
racy (within 12
months, 25℃ ±5℃)
±(%of Output
+Offset)
Setup Temperature
Coefficient ±(%of
Output/℃+Offset)
Read Back Temper-
ature Coefficient
±(%of Output/℃
+Offset)
Dynamic
Output parameter
Setup stability-
30min (%of Output
+Offset)
Setup stability-8h
(%of Output
+Offset)
Readback stability-
30min (%of Output
+Offset)
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Voltage
Current
Voltage
Current
Rising slope
Falling slope
Dynamic
Frequency
Min. rise time
Output voltage
range (Three-
phase four-wire)
Output frequency
range
Maximum output
current (rms)
Power factor
Islanding protection
Voltage
Current
Voltage
Current
Voltage
Current
Copyright © Itech Electronic Co., Ltd.
Technical Specification
IT6012B-300-150
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.5% + 0.5%FS
≤1% + 1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.5% + 0.5%FS
≤1% + 1%FS
≤50PPM/℃
≤200PPM/℃
≤50PPM/℃
≤200PPM/℃
150A/ms
150A/ms
500Hz
≤1ms
198V~264V (Derating 50%)
342V~528V
47Hz~63Hz
L1,L2/20A;L3/34A
≥0.99
Active islanding protection
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
247