Parameter
Setup Resolution
Read Back
Resolution
Setup Accuracy
(within 12 months,
25℃ ±5℃) ±(%
ofOutput+Offset)
Read Back Accu-
racy (within 12
months, 25℃ ±5℃)
±(%of Output
+Offset)
Setup Temperature
Coefficient ±(%of
Output/℃+Offset)
Read Back Temper-
ature Coefficient
±(%of Output/℃
+Offset)
Dynamic
Output parameter
Input resistance
Min. operating
voltage
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Voltage
Current
Power
Resistance
Voltage
Current
Voltage
Current
Rising slope
Falling slope
Dynamic Frequency
Min. rise time
Output voltage
range (Three-phase
four-wire)
Output frequency
range
Maximum output
current (rms)
Copyright © Itech Electronic Co., Ltd.
Technical Specification
IT6018B-300-225
0.001~7500Ω
1.6V at 225A
0.01V
0.01A
0.001kW
0.001Ω
0.01V
0.01A
0.001kW
0.001Ω
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.5% + 0.5%FS
≤1% + 1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.5% + 0.5%FS
≤1% + 1%FS
≤50PPM/℃
≤200PPM/℃
≤50PPM/℃
≤200PPM/℃
225A/ms
225A/ms
500Hz
≤1ms
198V~264V (Derating 50%)
342V~528V
47Hz~63Hz
28A