Parameter
Output parameter
Setup stability-
30min (%of Output
+Offset)
Setup stability-8h
(%of Output
+Offset)
Readback stability-
30min (%of Output
+Offset)
Readback stability-
8h (%of Output
+Offset)
Input impedance
quiescent current
Efficiency
Remote Sense
Compensation
Voltage
Command Re-
sponse Time
Storage
Temperature
Protective Function
Standard Interface
Isolation (input to
ground)
Falling slope
Dynamic
Frequency
Min. rise time
Output voltage
range (Three-phase
four-wire)
Output frequency
range
Maximum output
current (rms)
Power factor
Islanding protection
Voltage
Current
Voltage
Current
Voltage
Current
Voltage
Current
OVP, OCP, OPP, UVP, OTP, Vsense protect
Standard: USB, CAN, LAN, VCP,
Copyright © Itech Electronic Co., Ltd.
IT6006B-800-25
25A/ms
500Hz
≤1ms
198V~264V (Derating 50%)
342V~528V
47Hz~63Hz
L1,L2/20A;L3/0A
≥0.99
Active islanding protection
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
≤0.02% + 0.02%FS
≤0.1% + 0.1%FS
<4mA at Vmax
~92%
≤8V
2Ms
-10℃~70℃
optional: GPIB, RS232
1500V
Technical Specification